Firmware 4.16 released!

 https://www.rhelectronics.store/nuclear-pioneer-mca-multichannel-analyzer-firmware-updates

What is new in 4.16 firmware:

  1. Introduced new 3+1 Points method for Energy Scale calibration. 

  2. Added more Color Themes to the spectra. To switch the theme toggle encoder to the pointer scrolling and turn it few times toward 0keV direction.

  3. Added Lu-176 to the library of RIID.

  4. Improved Tc-99m detection.

  5. Improved U-235 detection.

  6. Fixed bug with Lu-177 label pop-up under Tc-99m peak.








Saturday, February 4, 2023

Firmware update 4.14 released for Nuclear Pioneer RIID

Firmware update 4.14 released for Nuclear Pioneer RIID based on Cortex-M4. You are welcome to download the latest firmware file including programming instruction PDF here:

Nuclear Pioneer MCA Firmware | RH Electronics

What is new in 4.14 firmware:

  1. In scintillation mode added Waterfall Histogram for energy distribution and CPS intensity estimation. The scale has the same zoom settings as the main MCA window: 512-4096 channels.  Waterfall zoom can be set in the LCD ZOOM X menu.

  2. In scintillation mode added basic identification for Am-241, Cs-137, Ra-226, U-235. Please note, scintillation mode identification does not replace the main MCA RIID mode and has less performance of the identification results compared with the MCA mode. However, it can be a nice add-on along with the new Waterfall Histogram.

  3. Fixed bug in CSV file date. Now the day and month of the recorded CSV spectrum are displayed correctly.

  4. Improved activity calculator. Now it has a better precision function to get efficiency for the selected geometry. You may need to re-calibrate the correction factor in the activity menu.

  5. Improved geometry selection menu. Now the menu scrolling list starts with the previously selected crystal size. 

  6. Fixed a few small bugs in the internal maintenance. 

  7. Added internal test for erratic value or temperature sensor disconnection. Now if the sensor read wasn't completed, the temperature readings will be displayed as "--.-" until the next read try. 




Friday, September 30, 2022

 

15% OFF Discount Coupon Code: TISHREI
for use on rhelectronics website
Valid until 18/10/2022

Sunday, April 24, 2022

Nuclear Pioneer firmware update 4.12

 https://www.rhelectronics.store/nuclear-pioneer-mca-multichannel-analyzer-firmware-updates

What is new in 4.12 firmware:

  1. Library is structured into two groups. Now you can set in the RIID f(x) menu what type of the library to use: Industrial/N.O.R.M or Medical. Selected library hint is also shown on the main display as MED or IND. IND/N.O.R.M. includes:Cs-137, Am-241, Co-60, Co-57, Ba-133, Eu-152, Ra-226, Th-232, U-235, K-40  MED includes: I-131, Lu-177, F-18(beta) and following isotopes as it also used in Nuclear Medicine for calibration or procedures: Cs-137, Co-60, Co-57

  2. I-131 assigned to the correct Medical classification.

  3. Fixed false positive detection of I-131 caused by Ba-133 peaks

  4. Fixed false positive detection of Bi-214 caused by Lu-177

  5. Start logo of the device is replaced with a smaller image to free 137kBytes of storage memory for further updates.

  6. Added F-18 511keV to the medical library, currently in beta mode.

  7. Added blink notification for successful identification.  






Thursday, September 30, 2021

Nuclear Pioneer 4.06 firmware update

 What is new in 4.06 software:

  1.  Optimized and faster peak detection
  2.  Fixed false positive detection triggering in some scenarios 
  3.  Improved Ba-133 and Lu-177 detection
  4.  Improved Cs-137 FWHM% resolution calculation
  5.  Added 3 minutes warning for warm-up period after power up
  6.  Added energy calibration hints with markers and energies list for the selected scheme
  7.  Added Co-57 I-131 energy calibration scheme










Friday, September 3, 2021

Nuclear Pioneer MCA 4.05 firmware update

 4.05 firmware update released for Nuclear Pioneer MCA. Now you can download the latest firmware file including programming instruction PDF here:

https://rhelectronics.net/store/nuclear-pioneer-mca-multichannel-analyzer-firmware-updates

What is new in 4.05 software:
1. Added second color theme for gamma spectrum with higher contrast. You can switch the spectrum color by making several turns of the encoder pointer toward 0keV direction. The encoder have to be in pointer control mode.
2. Added Th-232, Ba-133, Lu-177 isotopes to the auto-detection library
3. Added N.O.R.M. mix detection with mixed Ra-226 and Th-232
4. Improved peak detection
5. In scint.mode, the counter will make the event beep for every n=100 detected particle for large crystal or for every n=25 detected particle when small crystal is used. You can set crystal size through serial monitor command as described in the manual.
All previous bug fix and updates from 4.01-4.04 are included in 4.05
You may need to recalibrate LLD, HLD, doserate factors, timestamp and energy scale after making firmware update.









Sunday, August 1, 2021

Summer Sale 10% Off

Summer Sale started: 10% Cart Discount for all items on rhelectronics.net website!

valid until 15 August.

Wednesday, July 28, 2021

4.02 firmware update released for Nuclear Pioneer MCA

 4.02 firmware update released for Nuclear Pioneer MCA. You can download the hex file from rhelectronics website:

What is new in 4.02:
 
Added boot screen to allow viewing of all saved constants
Added click sound for Geiger-Muller counter in scintillation mode
Improved averaging procedure of Geiger-Muller CPS counter, now it show the correct result faster
Added serial command to make a training data of isotopes for better and faster identification, see updated manual for details
Added serial command to set crystal size, 51x51mm or 25x25mm
Improved doserate energy compensation calculation
Fixed bug of non correctly saved mean CPS to eeprom memory
 
You must to recalibrate LLD, HLD, doserate factors, timestamp and energy scale after making firmware update. For fimrware update instruction please download user manual PDF.



Friday, July 23, 2021

Just few photos

 Nuclear Pioneer MCA with 4.01 firmware. Just few photos with Ra-226 and Cs-137





Tuesday, July 13, 2021

Firmware update released for Nuclear Pioneer MCA

 


4.01 firmware update released for Nuclear Pioneer MCA. You can download the hex file from rhelectronics website:

What is new in 4.01:

1. Better and faster Cs-137, Am-241 and Ra-226 RIID detection. Reduced the number of false detection events
2. Added few BLE commands for calibration through smartphone terminal application, see user manual for more details
3. Changed starting position of a channel pointer during energy calibration
4. Minor changes in battery voltage monitoring and initial ADC configuration
You must to recalibrate LLD, HLD, doserate factors, timestamp and energy scale after making firmware update. For fimrware update instruction please download user manual PDF.


Wednesday, June 2, 2021

Nuclear Pioneer MCA Gamma Spectrometer

 


Assembled unit with enclosure and battery can be ordered from RH Electronics website:

https://rhelectronics.net/store/nuclear-pioneer-mca-multichannel-analyzer-for-gamma-spectrometry.html

The MCA can work as a robust Gamma Spectrometer and as a Scintillation Counter Survey Meter. It has high count rate performance for spectrum mode and for scintillation search mode.

MCA ver.4 specifications:

  • ARM Cortex-M4 microprocessor
  • 12-bit 4096 channels ADC
  • TFT LCD 3.5” 480x320 with adjustable backlight level
  • Rotary Encoder for controls
  • 600V-1000V adjustable high voltage for photomultiplier probe positive polarity (NaI(Tl) probe is not included)
  • 400V high voltage for an internal Geiger Counter
  • Include tiny internal Geiger Counter sensor
  • Adjustable gain & pulse shape pre-amplifier for an external photomultiplier probe
  • Gamma Spectrometer Mode (tested up to 10.000 CPS)
  • Scintillation Counter Mode with PMT and GM Sensor
  • Easy Channel to Energy calibration with selectable scheme and channels pick
  • Real time background subtract mode for gamma spectrometer
  • Real time gaussian peak detection
  • Linear or Logarithmic spectrum viewer
  • Energy compensated dose rate
  • 0.30 uSv/h doserate alert and 2-sigma CPS alert in scint.mode
  • CPS standard deviation calibration for scint.mode
  • Mute / Alert / Clicking in scint.mode
  • Spectrum LCD zoom 512-4096 channels
  • Micro SD card for data storage, include SD card
  • RTC (include installed CR2032 battery for date and time keeping)
  • Internal temperature sensor
  • Bluetooth BLE module (optional)
  • 12Mbit USB port for programming, calibration or data transfer
  • Easy firmware update via USB and friendly bootloader
  • Power supply: 3.7V LiPo battery, battery current consumption 250mA-350mA, LiPo included
  • 3.7V LiPo battery USB charger, software low battery alert
  • UPC number: 634154871201
  • SKU: RH-MCA-4

Saturday, December 5, 2020

DIY Kit USB Gamma Spectrometer Electronic board for MPPC SiPM 60035 Theremino

 


Technical specifications:

  • SiPM Bias Voltage 30V with fine Vbr adjustment
  • USB Audio ADC for direct compatibility with Theremino, PRA or BecqMoni MCA
  • Temperature dependence slope: 19mV/C-25mV/C
  • Dimensions: 106x26 mm

Buy the DIY Kit with enclosure on eBay https://www.ebay.com/itm/324405513719 

Buy Electronics board only https://rhelectronics.net/store/mppc-sipm-usb-gamma-spectrometer-driver-board-for-microfc-60035-with-audio-adc.html

Electronic driver board for DIY Gamma Spectrometer based on MPPC Silicon Photomultiplier (SiPM). It made to support Sensl MicroFC 60035 by default, however it electrically compatible with other 30V SiPM with temperature dependence of ~21mV/C

The board sold soldered and tested, without SiPM and without crystal. Recommended for usage with MicroFC 60035 silicon photomultiplier and 8x8x50 CsI(Tl) crystal. The board has space for installing 8x8x50mm detector and the overall PCB size made for Hammond 1593DBK enclosure. 

Electronics intended to wotk in temperature range of 10C-30C, try to install the SiPM detector close as possible to the thermistor sensor on the PCB as shown on the diagram.

Windows OS detects the board as an USB Audio device, that's why you can start to use your favorite freeware MCA without additional audio card or any adapters. Just solder USB cable and open Theremino, PRA or BecqMoni2011 MCA.

Calibration process is simple!

  1. Set recording audio level to 99%, set playback audio level to 0% in Windows drivers
  2. Set Theremino Audio Gain x1 and 192kHz sampling rate for the USB device
  3. Set Theremino Energy Trimmer to the middle
  4. Apply Cs-137 and adjust SiPM voltage bias potentiometer to place the 662keV at correct position
  5. Check the bias voltage on SiPM cathode is below 31V and re-adjust Energy Trimmer or Bias (if required)


Gamma Spectrum with Theremino MCA and 8x8x50mm CsI(Tl) detector made with the driver:







Tuesday, October 13, 2020

SiPM MPPC USB Gamma Spectrometers for Theremino / PRA / BecqMoni2011 MCA

https://www.ebay.com/itm/224192491790 

http://www.ebay.com/itm/224175678401

For sell, SiPM detectors with CsI(Tl) crystal. 

Complete USB Gamma Spectrometer with audio interface for amateur freeware Windows MCA software like Theremino or PRA 

Just plug into PC and start using it!

Price depend on crystal size and energy resolution.

  • Dimensions: 114x36x20mm
  • Crystal CsI(Tl) 8x8x50mm or 6x6x30mm 
  • MPPC SiPM MICROFC detector with thermo-compensated power supply
  • USB audio interface for Windows
  • Detection range: 32keV - 3000keV




Friday, May 15, 2020

Firmware 1.06 update for MCA ver.1 boards!

1.06 firmware update released for the MCA ver.1 boards! It include supporting of UART-USB logging with the PC Utility software. You can download firmware update and utility software from the rhelectronics website.

https://rhelectronics.net/store/diy-pic18-mca-kit-for-gamma-spectroscopy.html

What is new in 1.06 firmware:
- UART Mode for live spectrum transfer
- Added new hex format for SD file (faster saving)
Firmware can be uploaded to the module with Pickit programmer. To start using UART-USB all you need is CP2102 USB-TTL module to connect the MCA with the computer.
The PC Utility software will do: live spectrum, import and export CSV, SD file convert from hex to CSV, export spectrum screenshot and bin to energy calibration. PC Utility software working as a passive receiver, I'll post communication standards of the MCA unit if you want to implement your own UART data receiving of the gamma spectrum from the MCA.



Sunday, April 5, 2020

MCA Terminal configuration software for MCA ver.3

https://rhelectronics.net/store/mca-terminal.html

MCA Terminal is a calibration terminal software for MCA ver.3 Multi Channel Analyzer. The software will allow you to perform channel to energy calibration of the unit, visually estimate calibration function linearity, download and view CSV data files from the unit memory, make quick erase of the entire data storage, export spectrum screenshots and send any custom command to the unit.
Current version of the software is the beta version, you are welcome to send me an email if you see any bug. The software require Microsoft .NET Framework 4.5.2 installed on your computer.

Friday, March 27, 2020

10% Discount Coupon Code: stayhome

10% Discount Coupon Code: stayhome
For purchase on rhelectronics.net website, valid by 30 April 2020.
Apply in your shopping cart before checkout.